          CY-RCT02A1(5) Clamp-on Flexible Rogowski Coil Split Current Transformer

          "CY-RCT02A1 (5)" Type 1 (5)A Rogowski coil split current transformer provides easy-to-install plug-and-play solution that can be connected to a power meter or a 1(5)A current transformer Equipment used in conjunction.

          The Rogowski coil split current transformer Kit has a three-channel 1(5)A integrator output that can be used for most power meters and devices with 1 (5) A input. The kit offers four selectable measurement ranges including: 500A, 1kA, 2.5kA and 5kA, the detection range of 0.5% to 120% of the rated current input .Applied to 50 / 60Hz system, the rated frequency range of 45Hz to 65Hz. The mounting bracket is DIN rail or surface mount, with 24Vdc power supply.



          Application Uses: power instrumentation, electronic multi-function energy meter and field calibrator, instrumentation measurement and protection.

          Features:

          No need to disconnect the bus line power outage, easy installation.

          Simple and quick installation in a small space;

          Fine design, coil size can be customized

          Excellent linearity;

          Dimension and wire schematic


          DESCRIPTION

          Model code:

          Technical data:


           

          No.

          Technical data

          data

          Note

           

          Range of current measurement 

          0.5 - 5000 A

          80 dBSignal range

           

          Output

          0 - 5 ARMS

           

           

          Variable range stalls

          500A,1kA,2.5kA,5kA

          selectable

           

          Max burden

          1.25 VA each channel

           

           

          Max output

          impedance

          50 mΩ

           

           

          Measuring channel

          Single / three phase

           

           

          frequency

          50/60 Hz

           

           

          Ratio error

          ±1%

           

           

          Phrase error

          < 1.5 ° @ 50Hz

           

           

          Linearity

          ±0.3% 5% - 120%In

           

           

          Position sensitivity

          ±2%

           

           

          Field effect

          ±1% Range (distance coil)200mm

           

           

          environment

          Indoor

           

           

          Power requirements

          voltage48VDC ±10%,30w

           

          current0.6安培 DC @ 48VDC

           

           

          Cable length

          2mMeasuring head to electronic module

           

           

          output/input connection

          18 - 28 AWG / 12 - 18 AWG

           

           

          Operating temperature 

          -20-40

           

           

          Relative humidity

          5%?95no Condensation 

           

           

          Accessories 

          TS35/7 DIN installation trail

           

          Note All precision is specified at 20 ° C and the coil is centered on the conductor. Typical accuracy of the coil <1%。

          Dimension and  schematic 

          The match coil can be our “CY-RCT01”or“CY-RCT02” series, or customized also.


          Function and Application 

          Function General measurement and protection in power systems for highly mobile or space-constrained or uninterrupted power systems.

          Application Uses: power instrumentation, electronic multi-function energy meter and field calibrator, instrumentation measurement and protection.


          Installation instruction:


          Attention:



          When flexible rogowski coil  measurement probe connected, the cable under test should be placed in the middle of the flexible rogowski coil and the coil can be kept vertical to effectively reduce the measurement error.

          in daily use , please ensure the correct connection of the XS1 terminals  positive and negative polarity of the power supply, once incorrect connection, the inside chip will be damaged.

          If the output channel for more than 5 amps RMS may cause RōCoilTCA-5 to overheat and damage.

           


          Contact Us

          Email: international2@chuangy.com

          Address: 1F and 4F block B,Jiada R&D Bldg, High-tech Park,Nanshan,Shenzhen,China

          Post code :518057

          Tel. 0086-755-86000713


          Copyright © 2019. Shenzhen Chuangyin   Co., Ltd. All rights reserved. 粵ICP備11018302號
          日本乱偷人妻中文字幕_日本高清中文字幕在线观穿线视频_多人强伦姧人妻完整版
          <em id="fhk4q"></em>
        2. <dd id="fhk4q"></dd>
          <button id="fhk4q"></button>
          
          

          <tbody id="fhk4q"></tbody>
          1. <tbody id="fhk4q"></tbody>

                <th id="fhk4q"><track id="fhk4q"></track></th>
              1. <button id="fhk4q"><object id="fhk4q"></object></button>
                <rp id="fhk4q"><object id="fhk4q"><input id="fhk4q"></input></object></rp>