          PRODUCTS
          Locatin : Products > Instrument Transformers > MV & LV CT PT > Outdoor CT/PT
          JSZXW18-12 OUTDOOR COMBINED TRANSFORMER

          12kV Outdoor Three-Phase Epoxy Resin Type:
          This three phase, six compositions combined CT&VT, consists of three semi-insulation VTs of Y-Y wiring and three CTs series connected with phase A,B,C. Secondary leads in junction box is easy for wiring and testing. Use epoxy resin insulation stunt structure for outdoor installation. Applicable for highest voltage for equipments no more than 24kV for metering/measuring measurement in power system.



          DESCRIPTION

          Technical Data:
          1.Installation site         Outdoor
          2.Rated Frequency           50/60Hz
          3.Burden power factor       COSФ=0.8(lagging)
          4.Technical standard accords wiht    IEC 60044-1&2


          Specification:

          Model

          Rated

          Primary

          Voltage

          (kV)

          Rated

          Secondary

          Voltage

          (kV)

          Accuracy

          Class

          Rated Output

          (VA)

          Limited Output

          (VA)

          Rated

          insulation

          level

          (VA)


          JSZXW18

          -12

          12.47/√3

          10/√3

          0.12

          0.1

          0.1/√3

          0.2

          0.5

          25

          50

          1000VA

          12/42/75 GB

          17.5/38/75 IEC

          Note: Upon request we are glad to offer transformers accordign to other technical specs.


          Application:
          Use for highest voltage for equipments no more than 17.5kV,for current/voltage measurement in power system.


          Features:
          1.use high properties iron core to meet high accuracy,big burden etc.
          2.use epoxy resin cast insulation structure to improve anti-pollution,anti-moisture etc.
          3.use full-sealed cast insulation type.


          Outline Drawing:



          Contact Us

          Email: international2@chuangy.com

          Address: 1F and 4F block B,Jiada R&D Bldg, High-tech Park,Nanshan,Shenzhen,China

          Post code :518057

          Tel. 0086-755-86000713


          Copyright © 2019. Shenzhen Chuangyin   Co., Ltd. All rights reserved. 粵ICP備11018302號
          日本乱偷人妻中文字幕_日本高清中文字幕在线观穿线视频_多人强伦姧人妻完整版
          <em id="fhk4q"></em>
        2. <dd id="fhk4q"></dd>
          <button id="fhk4q"></button>
          
          

          <tbody id="fhk4q"></tbody>
          1. <tbody id="fhk4q"></tbody>

                <th id="fhk4q"><track id="fhk4q"></track></th>
              1. <button id="fhk4q"><object id="fhk4q"></object></button>
                <rp id="fhk4q"><object id="fhk4q"><input id="fhk4q"></input></object></rp>