          LZZW-36 Outdoor Current Transformer

          Epoxy resin casting insulation and fully enclosed support construction, encloses the primary & secondary windings and annular core in the epoxy resin casting body. The product has large periphery insulation creepage distance, withstanding dirtiness and dampness. Be suitable for measuring electric capacity, current and protective relaying in the power system of 36kV (Up to 40.5 kV).

          DESCRIPTION

          Main technical parameter

          1.  Rated voltage: 30 kV or 33 kV or 34.5kV or 35kV etc

          2.     Rated secondary current:5Aor1A

          3.     Rated insulation level: 36/70/170 kV (40.5/95/200 kV)

          4.     Standards: IEC60044-1.2003 Part 1: Instrument transformers-Part1: Current transformers

          5.     Other technical parameter pls see as follow

          Single ratio

          Rated current ratio (A)

          Accuracy classes combination

          Rated output

          (VA)

          FS

          ALF

          Rated short-time thermal current (kA/S)

          Rated dynamic current ( kA)

          Measuring

          Protective

          0.2S

          0.5

          10P

          30-200/5

          0.2(S)/0.2(S)

          0.2(S)/0.5

          0.2(S)/10P

          0.5/10P

          10

          15

          15

          20

          20

          25

          5

          (10)

          10

          15

          20

          150I1n

          375I1n

          300/5

          31.5

          80

          400/5

          40

          100

          500/5

          50

          100

          600/5

          63

          130

          800/5

          80

          160

           

          Double ratio

          Rated current ratio (A)

          Accuracy classes combination

          Rated output

          (VA)

          FS

          ALF

          Rated short-time thermal current (kA/S)

          Rated dynamic current ( kA)

          Measuring

          Protective

          0.2S

          0.5

          10P

          30-60/5

          0.2(S)/0.2(S)

          0.2(S)/0.5

          0.2(S)/10P

          0.5/10P

          10

          15

          15

          20

          20

          25

          5

          (10)

          10

          15

          20

          2

          5

          50-100/5

          8

          20

          100-200/5

          15

          37.5

          200-400/5

          30

          75

          400-800/5

          63

          130

          Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

          Outline drawing



          Contact Us

          Email: international2@chuangy.com

          Address: 1F and 4F block B,Jiada R&D Bldg, High-tech Park,Nanshan,Shenzhen,China

          Post code :518057

          Tel. 0086-755-86000713


          Copyright © 2019. Shenzhen Chuangyin   Co., Ltd. All rights reserved. 粵ICP備11018302號
          日本乱偷人妻中文字幕_日本高清中文字幕在线观穿线视频_多人强伦姧人妻完整版
          <em id="fhk4q"></em>
        2. <dd id="fhk4q"></dd>
          <button id="fhk4q"></button>
          
          

          <tbody id="fhk4q"></tbody>
          1. <tbody id="fhk4q"></tbody>

                <th id="fhk4q"><track id="fhk4q"></track></th>
              1. <button id="fhk4q"><object id="fhk4q"></object></button>
                <rp id="fhk4q"><object id="fhk4q"><input id="fhk4q"></input></object></rp>